B&K Precision 2552-2559 - Manual User Manual

Page 43

Advertising
background image

43

7. If FFT display on full screen, press CH1 button again to

remove channel waveform display.

8. Press the “CURSOR” button to enter “Cursor” menu.

9. Press the “Cursor Mode” button to select “Manual”.

10. Press the “Type” option button to select “Voltage”.

11. Press the “Source” option button to select “FFT”.

12. Press the “CurA” option button and turn the “Universal”

knob to move Cursor A to the highest point of the FFT

waveform.

13. Press the “CurB” option button, turn the “Universal”

knob to move Cursor B to the lowest point of the FFT

waveform.

14. The amplitude (△V) displays on the top of the left screen.

Figure 25 - Measuring FFT Amplitude

2. Measure FFT Frequency

1. Press the CURSOR button.

2. Press the “Cursor Mode” button to select “Manual”.

3. Press the “Type” option button to select “Time”.

4. Press the “Source” option button to select “FFT”.

5. Press the “CurA” option button and turn the “Universal”

knob to move Cursor A to the highest position of the FFT

waveform.

6. The value of CurA displaying on the top of the left screen

is the highest Frequency. This frequency should be the

same as input signal frequency.

Advertising