B&K Precision 2552-2559 - Manual User Manual

Page 64

Advertising
background image

64

Table 23 - Set Trigger Mode to Pulse Trigger Function Menu 1

Option

Setting

Description

Type

Alternate

The trigger signal comes from two

vertical channels when you use

alternative trigger. In this mode,

you can observe two irrelative

signals at the same time.

Channels

CHX-CHY

Select any two channels from CH1,

CH2, *CH3, or *CH4 as the sources

for alternating trigger.

Source

CH1, CH2,

*CH3, *CH4

Selects the source channel.

Mode

Pulse

Set trigger type of the vertical

channel signal (selected by Source)

to Pulse trigger.

Next Page

Page 1/2

Enter the second page of

Alternative trigger menu.

*Available for 4CH models only.

Table 24 - Set Trigger Mode to Pulse Trigger Function Menu 2

Option

Setting

Description

When

Select how to compare the trigger

pulse relative to the value selected

in the Set Pulse Width option.

Set Width

20.0 ns~10.0 s

Selecting this option can turn the

universal to set up the pulse width.

Set up

Enter the “Trigger Setup Menu”

Next Page

Page 2/2

Press this button to return to the

first page.

Advertising