B&K Precision 2552-2559 - Manual User Manual

Page 91

Advertising
background image

91

If you want to measure voltage parameters, please follow the steps

below:

1. Press the “MEASURE” button to enter the “Auto measurement”

menu.

- Wid

-Width Measures the time between the first

falling edge and the next rising edge at the

waveform 50% level.

+ Duty

Measures the first cycle waveform.

Positive Duty Cycle is the ratio between

positive pulse width and period.

-Dut

y

Measures the first cycle waveform.

Negative Duty Cycle is the ratio between

negative pulse width and period.

Phase

The amount one waveform leads or lags

another in time. Expressed in degrees, where

360 degrees comprise one waveform cycle.

FRR

The time between the first rising edge of

source 1 and the first rising edge of source 2.

FRF

The time between the first rising edge of

source 1 and the first falling edge of source 2.

FFR

The time between the first falling edge of

source 1 and the first rising edge of source 2.

FFF

The time between the first falling edge of

source 1 and the first falling edge of source 2.

LRR

The time between the first rising edge of

source 1 and the last rising edge of source 2.

LRF

The time between the first rising edge of

source 1 and the last falling edge of source 2.

LFR

The time between the first falling edge of

source 1 and the last rising edge of source 2.

LFF

The time between the first falling edge of

source 1 and the last falling edge of source 2.

Advertising