32 - 8630

S

YSTEM

D

ESCRIPTION

Binary outputs

electrically isolated

current limitation

100 mA, output is clocked

Binary input

electrically isolated

0 ... 5 V = log "0", 10 ... 30 V = log "1"

inverted output reversed accordingly

PNEUMATIC DATA

Control medium

Qualitiy Classes to DIN ISO 8573-1

Dust content

Class 5
max. particle size 40 µm, max. particle density 10 mg/m

3

Water content

Class 3
max.pressure dew point
- 20 °C or min. 10 deg. below the lowest operating temperature

Oil content

Class 5
max. 25 mg/m³

Temperature range of
compressed air

-10 ... + 50 °C

Pressure range

3 ... 7 bar

Supply pressure variation

max. ± 10 % during operation

Air flow capacity of
control valve

100 l

N

/ min STP (for pressurizing and exhausting)

(Q

Nn

- value acc. to definition on pressure drop from 7 to 6 bar abs.)

Intrinsic air consumption
with zero control output

0.0 l

N

/min STP

Connections

G 1/4’’ internal thread G / NPT / RC