ZOLL E Series Monitor Defibrillator Rev D User Manual

Page 3

Advertising
background image

9650-1450-01 Rev. D

1

Table of Content

Chapter 1 Maintenance Tests

Overview .................................................................................................................................................................... 1-1

Before You Begin the Maintenance Tests............................................................................................................... 1-2

Equipment that You Need to Perform the E Series Maintenance Tests............................................................... 1-3

Equipment You Need for the E Series Options Maintenance Tests ..................................................................... 1-3

Physical Inspection of the Unit .............................................................................................................................. 1-5
Front Panel Button Test ........................................................................................................................................ 1-7
3, 5, and 12 Leads Test ...................................................................................................................................... 1-10
Power Supply Test (Optional) ............................................................................................................................. 1-11
Leakage Current Test ......................................................................................................................................... 1-13
Paddles Test (If applicable) ................................................................................................................................ 1-14
Heart Rate Display Test ...................................................................................................................................... 1-15
Calibrating Pulses on Strip Chart Test ................................................................................................................ 1-16
Notch Filter Test ................................................................................................................................................. 1-17
Heart Rate Alarm Test ........................................................................................................................................ 1-18
Defibrillator Self Test .......................................................................................................................................... 1-20
Synchronized Cardioversion Test ....................................................................................................................... 1-22
Shock Test .......................................................................................................................................................... 1-23
Summary Report Test ......................................................................................................................................... 1-25
Advisory Message Test ...................................................................................................................................... 1-26
Pacer Test .......................................................................................................................................................... 1-27
SpO2 Monitor Test for SpO2 Option ................................................................................................................... 1-29
EtCO2 Monitor Test (for EtCO2 Option) ............................................................................................................. 1-31
Barometric Pressure Calibration Check .............................................................................................................. 1-32
CO2 Accuracy Check (Optional test to check EtCO2 sensor) ............................................................................ 1-33
NIBP Volume Leak Test with Fluke Biomedical NIBP Analyzer ......................................................................... 1-35
NIBP Transducer Calibration Test ...................................................................................................................... 1-37
NIBP Monitor Test .............................................................................................................................................. 1-39
Bluetooth Test ..................................................................................................................................................... 1-41