App index – Yokogawa Value Series FX1000 User Manual

Page 113

Advertising
background image

3-31

IM 04L21B01-17EN

Commands

1

2

3

4

5

6

App

Index

EV

Executes manual sample,

generates a manual trigger, takes

a snapshot, or causes a timeout

Syntax

EV p1<terminator>
p1 Action type

0

Executes manual sampling

1

Generates a manual trigger

2

Takes a snapshot

3

Causes a timeout in display data

4

Causes a timeout in event data

Example Execute manual sampling.

EV0

Description EV1 is only valid when the key trigger is set

to ON using the event data sample condition
command (the TE command). The EV1
command is equivalent to a key trigger.

CL

Executes manual SNTP (/C7

option)

Syntax

CL p1<terminator>
p1 Executes manual SNTP (0)

Example Synchronize the clock.

CL0

CV

Switches between the normal

and secondary trend intervals

Syntax

CV p1<terminator>
p1 Trend interval (0, 1)

0

Switches to the first trend interval
(the normal trend interval)

1

Switches to the secondary trend
interval

Example Set the trend interval to the secondary trend

interval.
CV1

MS

Writes a message (display and

write)

Syntax

MS p1,p2,p3<terminator>
p1 Message number (1 to 100)
p2 Message write destination

GROUP A specific display group
ALL

All display groups

p3 Display group number

The display group number when p2 is set

to GROUP.

This parameter has no meaning when p2 is

set to ALL.

Example Write the message in message number 8 to

display group 1.
MS8,GROUP,1

Description • If you omit p2, the message is written to all

display groups.

• Set p3 by referring to the table in section 3.3.

BJ

Writes a free message

Syntax

BJ p1,p2,p3,p4<terminator>
p1 Message number (1 to 10)
p2 Message (up to 32 characters)
p3 Message write destination

GROUP A specific display group
ALL

All display groups

p4 Display group number

The display group number when p2 is set

to GROUP.

This parameter has no meaning when p2 is

set to ALL.

Example

Using message number 3, write the string

ALARM” to all groups.

BJ3,ALARM,ALL

Description • If you omit p3, the message is written to all

display groups.

• Set p3 and p4 by referring to the table in

section 3.3.

EJ

Changes the password of the

login function (/C7 option)

Syntax

EJ p1,p2,p3<terminator>
p1 Old password (up to 8 characters)
p2 New password (up to 8 characters)
p3 New password (up to 8 characters)

Example Change the password from “PASS001” to

“WORD005.”
EJPASS001,WORD005,WORD005

TL

Starts, stops, resets

computation (MATH) or clears

the computation dropout status

display (/M1, /PM1, and /PWR1

options)

Syntax

TL p1<terminator>
p1 Action type

0

Starts computation

1

Stops computation

2

Resets computation

3

Clears the computation data
dropout display

Example Start computation.

TL0

Description You cannot use this command while the FX is

saving or loading setup data.

DS

Switches between execution

modes (operation and basic

setting)

Syntax

DS p1<terminator>
p1 Mode

0

Operation mode

1

Basic setting mode

3.5 Control Commands