App index – Yokogawa Value Series FX1000 User Manual

Page 185

Advertising
background image

6-11

IM 04L21B01-17EN

Specifications

1

2

3

4

5

6

App

Index

Register

Description

Supplementary Information

Type

Access

Simultaneous

Access

Write

Read

410611

Free message writing

Message number (1 to 10)

INT16

W

410612

Message write destination

INT16

W

0: All groups. 1 to 10: Specified group number.

410613

Specified value.

INT16

W

410614 to

410631

Free message
Up to 18 registers (up to 35 characters with '¥0'

termination).
The message must be 32 characters or less.

STR36

W

410632 to

410680

(Reserved) Free

message

-

-

-

Notation used in the Access column
W: Writable
R: Readable
If you read a write-only (W) register, zero is always read.
If you write to a read-only (R) register, an error will occur.

Notation used in the Simultaneous access column
Blank: Indicates a range of registers that can be written to or read from simultaneously.

You cannot simultaneously access across a solid line.

-:

Not accessible.

6.3 Modbus Protocol Specifications

Advertising