Yokogawa Value Series FX1000 User Manual

Page 59

Advertising
background image

1-51

IM 04L21B01-17EN

Using the Ethernet Interface (/C7 Option)

1

2

3

4

5

6

App

Index

Setting the FX1000 Client (Modbus Client)

Assumes the settings other than that for the server and the command are left to default
values.

Registering the Destination Server

Register the FX1000 server to number 1.
The IP address of the FX1000 server is “190.168.1.101” as an example.
◊ Press

MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic

setting mode), and select the

Menu tab > Communication (Ethernet) > Modbus

client > Modbus server settings.

Item

Settings

Port

502

Modbus server name

192.168.1.101

Unit

Auto

Setting Command

◊ Press

MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic

setting mode), and select the

Menu tab > Communication (Ethernet) > Modbus

client > Command settings.

Item

Settings

Command type

R-M

First and Last

C01

Server

1

Regi.

300001

Type

INT16

1.11 Usage Example of the Modbus Function

Advertising