BNC 1105 Universal Counter User Manual

Page 138

Advertising
background image

138

138

138

138

Return

The “100”, “50” or “0” PCT is returned.

Note

As the command *RST is executed, the noise immunity will be set to 50 PCT.

[:SENSe]EVENt[1|2]:LEVel[:ABSolute] <numeric value> [V]

Sets or queries the level of the center of the hysteresis window. The range is -5.125 to

5.125 volts for X1 attenuation and -51.25 to 51.25 volts for X10 attenuation. The

resolution is 0.0025V for X1 attenuation and 0.025V for X10 attenuation.

Return

Numeric data transferred as ASCII bytes in <NR3> format with six significant digits.

Note

Sending this command disables [:SENS]:EVEN[1

︱2]:LEV:AUTO

[:SENSe]EVENt[1|2]:LEVel[:ABSolute]:AUTO <Boolean>

Sets or queries the state of the auto-triggering.

When auto-triggering is enabled, the counter automatically measures and computes the

trigger level according to the percentage specified by the command :[:SENS]:EVEN[1︱

2]:LEV:REL. Also the counter measures and computes trigger level each time :INIT

or :INIT:COUNT ON command is sent.

When the auto-triggering is on, the counter checks for each measurement if the

measurement signal is triggering, and the counter will measure and compute a new

trigger level if no triggering is found.

Return

A single ASCII-encoded byte. 0 means OFF and 1 means ON.

Notes

This will be set to ON after the counter has been turned off or a remote interface

reset.

Specifying a trigger level by using the command [:SENS]:EVEN[1

︱2]:LEV[:ABS] to

disable auto-triggering.

[:SENSe]EVENt[1|2]:LEVel:RELative <numeric value> [PCT]