Weidmuller ACT20X User Manual
Page 137
Appendix D. Installation Drawings ACT20X-HUI-SAO (Universal Converter)
1066540000/01/12.11
137
Terminal (21-22)
Input
U
i
, V
max
30
V
I
i
, I
max
120
mA
P
i
900
mW
C
i
3
nF
L
i
2
µH
Terminal (22–21, 21–22)
Input
Group
C
o
L
o
L
o
/R
o
U
o
, V
OC
16.6 V
IIC or A, B
0.4 µF
1000 mH
25 mH/Ω
I
o
, I
SC
0.2 mA
IIB or C, E, F 2.3 µF
1000 mH
100 mH/Ω
P
o
0.8 mW
IIA or D, G
9.5 µF
1000 mH
200 mH/Ω
Terminal (41, 42, 43, 44) and (51, 52, 53, 54)
Supply / Output
U
m
253 V, max. 400 Hz
Terminal (51, 52)
Supply
Voltage
19.2…31.2 V DC
Terminal (43, 44)
Relay Output
Non Hazardous
Location
Zone 2 Installation
Voltage max.
250 V AC / 30 V DC
32 V AC / 30 V DC
Current max.
2 A AC / 2 A DC
2 A AC / 2 A DC
Power max.
500 VA / 60 W
64 VA / 60 W
Terminal (53, 54)
Status Relay
Non Hazardous
Location
Zone 2 Installation
Voltage max.
125 V AC / 110 V DC
32 V AC / 32 V DC
Current max.
0.5 A AC / 0.3 A DC
0.5 A AC / 1 A DC
Power max.
62.5 VA / 32 W
16 VA / 32 W