Weidmuller ACT20X User Manual

Page 88

Advertising
background image

88

1066540000/01/12.11

ACT20X-(2)HTI-(2)SAO-S

Illustration 7-26:

IECEx Installation Drawing (1)

Terminal CH1 (11, 12, 13, 14), CH2 (21, 22, 23, 24)

Ex Input

U

o

8.7

V

I

o

18.4

mA

P

o

40

mW

L

o

/R

o

892

H/

U

i

10

V

I

i

30

mA

C

i

30

nF

L

i

820

nH

Group

C

o

L

o

IIC 5

F 100

mH

IIB 50

F 300

mH

IIA 1000

F 700

mH