Weidmuller ACT20X User Manual

Page 51

Advertising
background image

Product Installation / Operation, ACT20X-HUI-SAO (Universal Converter)

1066540000/01/12.11

51

2-wire 4…20 mA Output

Signal range

4…20 mA

Load resistance

≤ (V

supply

– 3.5 V) / 0.023 A [Ω]

Load stability

≤ 0.01 % of span / 100 Ω

Max. external 2-wire supply

3.5…26 V DC

Effect of external 2-wire supply voltage variation

< 0.005 % of span / V

Relay Output

Safe Area

Zone 2 Installation

Voltage max.

250 V AC / 30 V DC

32 V AC / 30 V DC

Current max.

2 A AC / 2 A DC

2 A AC / 2 A DC

Power max.

500 VA / 60 W

64 VA / 60 W

Relay functions

Setpoint, Window, Sensor error, Power and Off

Hysteresis in % / display counts

0.1…25 % / 1…2999

On and Off delay

0…3600 s

Sensor error detection

Break / Make / Hold

Status Relay

Safe Area

Zone 2 Installation

Voltage max.

125 V AC / 110 V DC

32 V AC / 32 V DC

Current max.

0.5 A AC / 0.3 A DC

0,5 A AC / 1 A DC

Power max.

62.5 VA / 32 W

16 VA / 32 W

Power Supply

Supply voltage

19.2…31.2 V DC

Max. consumption

≤ 3.5 W

Fuse

1.25 A / 250 V AC

Isolation Voltages (reinforced insulation), Test/Operation

Inputs / outputs / supply

2.6 kV AC / 300 V AC

Status relay to supply

1.5 kV AC / 150 V AC

Environmental Specifications

Ambient temperature

-20…+60 °C

Storage temperature

-20…+85 °C

Relative humidity (non-condensation)

< 95 %

Advertising