C-30

EtherNet/IP Objects

Class Code

Instances

The number of instances depends on the maximum number of diagnostic
items in the device. The total number of diagnostic items can be read in
Instance 0, Attribute 2.

Class Attributes

DPI Diagnostic Object

Hexadecimal

Decimal

0x99

153

Instances (Dec.) Single-Drive Mode

Multi-Drive Mode

0 – 16383

Instances 0 – 16383 in the drive

Instances 0 – 16383 in Drive 0

16384 – 17407

Instances 0 – 1023 in the adapter

Instances 0 – 1023 in the adapter

17408 – 18431

Instances 0 – 1023 in the adapter

Instances 0 – 1023 in Drive 1

18432 – 19455

Instances 0 – 1023 in the slave

Instances 0 – 1023 in Drive 2

19456 – 20479

Not supported

Instances 0 – 1023 in Drive 3

20480 – 21503

Not supported

Instances 0 – 1023 in Drive 4

21504 – 22527

Not supported

Instances 0 – 1023 in the adapter

Attribute
ID

Access
Rule

Name

Data Type

Description

1

Get

Class Revision

WORD

1

2

Get

Number of
Instances

WORD

Number of diagnostic items in the
device

3

Get

ENUM Offset

WORD

DPI ENUM object instance offset

Advertising