Chapter

5

Using I/O Messaging

Chapter 5 provides information and examples that explain how to use a
ControlLogix controller to send I/O Messaging to control, configure, and
monitor a PowerFlex 40 drive.

Important: At the time of publication, only ControlLogix controllers

can make an EtherNet/IP network I/O connection as
described in this chapter; PLC-5’s and SLC’s cannot.
However, these controllers can perform control using
explicit messaging to the CIP Register object and PCCC
N41 and N42 files.

On EtherNet/IP, I/O messaging is used to transfer the data which
controls the PowerFlex drive and sets its Reference.

The EtherNet/IP adapter provides many options for configuring and
using I/O, including configuring the size of I/O by selecting the number
of attached drives (Single or Multi-Drive mode).

Chapter 3

,

Configuring the Adapter

, and

Chapter 4

,

Configuring the

Scanner or Bridge

, discuss how to configure the adapter and scanner or

bridge on the network for these options. The

Glossary

defines the

different options. This chapter discusses how to use I/O after you have
configured the adapter and scanner or bridge.

Topic

Page

Topic

Page

About I/O Messaging

5-1

Using Reference/Feedback

5-3

Understanding the I/O Image

5-2

Example Ladder Logic Program

5-3

Using Logic Command/Status

5-2

!

ATTENTION: Risk of injury or equipment damage exists. The
examples in this publication are intended solely for purposes of
example. There are many variables and requirements with any
application. Rockwell Automation, Inc. does not assume responsibility
or liability (to include intellectual property liability) for actual use of
the examples shown in this publication.

About I/O Messaging