Rockwell Automation 22-COMM-E EtherNet/IP Adapter User Manual

Page 29

Advertising
background image

Configuring the Adapter

3-5

By default, the adapter is configured so that you set its IP address, subnet
mask, and gateway address using a BOOTP server. If you want to set
these functions using the adapter’s parameters instead, you must first
disable BOOTP and then set the appropriate parameters in the adapter.

To disable the BOOTP feature

1. Set the value of Parameter 02 - [BOOTP] to Disabled.

Figure 3.4 Example BOOTP Screen on PowerFlex 4-Class HIM (22-HIM-*)

2. Reset the adapter. See

Resetting the Adapter

section in this chapter.

After disabling the BOOTP feature, you can then configure the IP
address, subnet mask, and gateway using the adapter’s parameters.

To set an IP address using parameters

1. Verify that Parameter 02 - [BOOTP] is set to Disabled. This

parameter must be set to Disabled in order to configure the IP
address using parameters.

2. Set the value of Parameters 03 - [IP Addr Cfg 1] through 06 - [IP

Addr Cfg 4] to a unique IP address.

Figure 3.5 Example IP Address Screen on PowerFlex 4-Class HIM (22-HIM-*)

Setting the IP Address, Subnet Mask, and Gateway
Address

Value Setting
0

Disabled

1

Enabled (Default)

BOOTP

Parameter:

#

002

0

VALUE

LIMITS

SEL

X

Default = 0.0.0.0

255 . 255 . 255 . 255

[IP Addr Cfg 1]

[IP Addr Cfg 2]

[IP Addr Cfg 3]

[IP Addr Cfg 4]

IP Addr Cfg 1

Parameter:

#

003

0

VALUE

LIMITS

SEL

X

Advertising