Powerflex 4 and powerflex 40 drives, Logic status word – Rockwell Automation 22-COMM-E EtherNet/IP Adapter User Manual
Page 150
D-2
Logic Command/Status Words
Logic Status Word
PowerFlex 4 and PowerFlex 40 Drives
Logic Bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Status
Description
x Ready
0 = Not Ready
1 = Ready
x
Active
0 = Not Active
1 = Active
x
Command
Direction
0 = Reverse
1 = Forward
x
Actual
Direction
0 = Reverse
1 = Forward
x
Accel
0 = Not Accelerating
1 = Accelerating
x
Decel
0 = Not Decelerating
1 = Decelerating
x
Alarm
0 = No Alarm
1 = Alarm
x
Fault
0 = No Fault
1 = Fault
x
At Speed
0 = Not At Reference
1 = At Reference
x
Main Freq
0 = Not Controlled By Comm
1 = Controlled By Comm
x
Operation
Command
0 = Not Controlled By Comm
1 = Controlled By Comm
x
Parameters
0 = Not Locked
1 = Locked
x
Digital Input 1
Status
x
Digital Input 2
Status
x
Digital Input 3
Status
(1)
x
Digital Input 4
Status
(1)
(1)
This status is available for only PowerFlex 40 drives with firmware version 2.xx (or higher).