Rockwell Automation 22-COMM-E EtherNet/IP Adapter User Manual
Page 28
3-4
Configuring the Adapter
Figure 3.2 New Entry Dialog Box
4. Edit the following:
5. Click OK to apply the settings. The adapter appears in the Relation
List with the new settings (
Figure 3.3
).
Figure 3.3 BOOTP Server Window with an Adapter in the Relation List
6. To assign this configuration to the adapter permanently, click
Disable BOOTP. When power is cycled on the adapter, it will use
the configuration you assigned it and not issue new BOOTP requests.
7. To save the Relation List, select File > Save.
Box
(1)
(1)
For definitions, refer to the
Glossary
.
Type
IP Address
A unique IP address for the adapter
Subnet Mask
The subnet mask for the adapter’s network
Gateway
The IP address of the gateway device on the adapter’s network
TIP: To enable BOOTP for an adapter that has had BOOTP
disabled, first select the adapter in the Relation List, then
click Enable BOOTP, and finally reset the adapter.