Interpreting Import/Export error messages 75

This error:

Means that:

What to do:

device error - no
device specified

a device has not been specified

Select OK, then select or enter a device.

device error -
device does not
exist

the specified device has not been defined

Select No to select or enter another device.

Select Yes to create a new device. This dialog box opens:

1. Select the type of device.

2. Enter the device address.

3. Select OK.

device error -
device not an SLC
processor

1

a file imported from APS format requires an
SLC processor, which was not defined

Select OK, then select an SLC device.

parse error

1

the selected source file was:

corrupted

unsupported type, or a type other than

the type selected

manually edited, with

uncorrected mistakes

Select OK to abort the Tag Import/Export utility.
Fix the bad file if necessary. Choose Import from the Tools menu again and
select the same or another file to be imported.

file error - the file
does not exist

1

the selected source file does not exist

Select OK. Select another source file or cancel.

file error - the file
already exists

2

the selected destination file is already in
the project

Select Yes to replace the file with the imported file.
Select No to cancel the import.

project error

the selected project does not exist

Select OK. Select another project or cancel.

1