Configuration Software Error and Warning Messages

C–2

Publication 2706-817

Message

What to do

Meaning

Cannot print line.

Failed to send a text string. This may be a
printer error. The printout is terminated.

Check the Print Setup settings, Print Spooler
settings and the printer.

Cannot print text string.

Failed to send a text string. This may be a
printer error. The printout is terminated.

Check the Print Setup settings, Print Spooler
settings and the printer.

Cannot read the Terminal Catalog datafile.

The CATALOG.DAT file is missing or
corrupted. This file stores the terminal type
that is selected when creating a new
application or changing the application to fit a
different terminal type.

Call A-B technical support.

Data format unknown for tag: [tag name].

Internal error.

Check tag information.
If error persists, call A-B support.

Enter tag name before pressing Edit Tag
button.

A tag must be named before it can be edited.

Enter tag name.

Environment variable ABIC_CONFIG not
defined.

The DOS environment variable
ABIC_CONFIG is required for the
INTERCHANGE comm. drivers to work
properly. It is not defined.

Edit the AUTOEXEC.BAT FILE to add the
ABIC_CONFIG variable to specify the location
of the INTERCHANGE comm. drivers and the
configuration utility, or reinstall
MessageBuilder software.

File Error – Cannot find ISPCORE.DLL.

MessageBuilder software would not start
because the default path C:\AB\BIN is missing
from AUTOEXEC.BAT file.

Check the AUTOEXEC.BAT file for the path.

Firmware Version is the same - no need to
load new.

The firmware in the Terminal is the same as
the firmware in the Terminal Upgrade
database.

No action is necessary.

Font file name not found in MBWIN.INI -
Corrupt or missing INI file.

Essential MessageBuilder startup information
cannot be acquired. The MBWIN.INI is corrupt
or missing.

Check the \windows\system\ directory for a
valid MBWIN.INI file. Reinstall
MessageBuilder software.

Incompatible AB Utilities version.

MessageBuilder software detected an
incorrect version of the Utilities software on
startup.

Reinstall the AB Utilities disk, or call
Allen-Bradley for support.

Insufficient available Windows resources to
run this application. Try closing some other
applications and try again.

Too many applications are running.

Close all running applications and try again.

INTERCHANGE Configuration Utility not
found at [DOS path]. Check ABIC_CONFIG
environment variable.

The InterChange Configuration Utility can not
be found at the DOS path location that is
specified by the variable ABIC_CONFIG.

Check that CFGIC.EXE exists at a location
that is consistent with the path specified by
ABIC_CONFIG. Reinstall MessageBuilder
software.

Low resource memory.

Low memory error.

Close other applications and try again.
If error persists, exit Windows, reboot the
computer, try again.

Low resource memory.
Unable to open additional windows.

Low memory error.

Close other applications and try again.
If error persists, exit Windows, reboot the
computer, try again.

MessageBuilder version [nn.nn] is not
compatible with the version of CMSERV.DLL
that is currently in memory. MessageBuilder
will exit.

Conflict between MessageBuilder and
PanelBuilder DLL files.

Exit PanelBuilder to unload the DLL and then
restart MessageBuilder before restarting
PanelBuilder.

MessageBuilder version [nn.nn] is not
compatible with the version of CTKRIO.DLL
that is currently in memory. MessageBuilder
will exit.

Conflict between MessageBuilder and
PanelBuilder DLL files.

Exit PanelBuilder to unload the DLL and then
restart MessageBuilder before restarting
PanelBuilder.