10–28

Terminal and Communication Setup

Publication 2706-817

4. Set the parameter values as needed.

Parameters

Default

Options

Baud Rate

9600

300, 600, 1200, 2400, 9600, 19,200,
38,400 bps

Data Bits

8

7, 8

Parity

None

None, Odd, Even

Stop Bits

1

1, 2

H/W Handshake

Disabled

Enabled, Disabled

Inter-Packet Delay

200 ms

50, 100, 150, 200, 250, 300, 350,
400, 450, 500 ms

For information on the Hardware Handshake parameter, see Page
4–29.

Note: The Inter-Packet Delay parameter is intended to allow a
Dataliner DL10, DL20 or DL50 time to process each message
packet before the next packet is sent from the master. The worst
case for the Dataliner family is 300 ms.

If the port is configured for an ASCII Input device, this option
does not apply.

5. Select OK to save the RS-232 settings and return to the Terminal

Setup dialog.