Defining tags – Rockwell Automation 2706-MB1 MESSAGEVIEW 421 SOFTWARE MANUAL User Manual

Page 84

Advertising
background image

4–36

Planning an Application

Publication 2706-817

Read or Write tags that define controller addresses for variables are
entered in the Tag Editor. See Page 8–2. A tag has the following
attributes:

Tag Attributes

Description

Tag Name

Unique name identifying tag address

Data Type

Bit, BCD, Unsigned/Signed Integer, Character Array

Array Size

Number of elements in a character array.
For other data types, leave blank.

Description

General description of the variable

Node Name

Name of the logic controller that will store the
address

Tag Address

Specifies word or bit location in controller memory

Initial Value

Value in tag address at powerup

Update Frequency

How often the tag address will be updated while the
operation is running

Scaling

Scale and scale offset values

Data Entry Limits

Upper and lower limits of data stored at tag address

Usage depends on the variable. These attributes can be entered only in the Form View.

The Tag Editor supports two different methods for entering tags:

Table View for entering multiple tags.

Form View for entering a single tag.

Table View

Form View

Tags are stored in a database that is referenced by a project name.
The project name is entered when creating a new application file.

Note: A project can be created only when a new application is
created. However, once it has been created, existing or new
applications may be assigned to it.

Defining Tags