Validation Error Messages

This appendix lists messages that may appear while validating an
application, whether on command or automatically before
downloading. Messages are listed alphabetically.

For messages that may appear during creation or editing of an
application, see Appendix C.
For messages that may appear during a download, see Appendix E.
For messages that may appear during a tag import or export, see
Page 8–22.

Message

Meaning

What to do

[Terminal Setup] Terminal selected in Terminal
Setup does not match Application Type.

The selected catalog number does not match
that of the application.

Change the catalog number using the
Terminal Setup dialog to change the MV Type
and Catalog and Version controls to match
that of the application, or press OK to the
Terminal Setup dialog to convert the
application to match the selected terminal
type.

Background message [number] doesn’t exist.

The assigned Background message is not
defined.

Define the Background message or disable
background message with the Terminal
Setup/Advanced dialog.

Bit Trigger Number [number] duplicated
[number] times.

The bit trigger numbers for all messages in an
application are not unique.

Use the Bit Trigger control on the Message
Editor Table View to change the bit number or
delete the offending message to insure that
bit trigger numbers are unique.

Bit Trigger Priority mismatch with undefined
Bit Triggered Messages.

Bit triggering is assigned priority over Value
triggering yet there are no Bit Trigger enabled
messages in the Application.

Use the Trigger Priority control on the
Terminal Setup/Advanced dialog to change
the priority to Value.

Bit Trigger Tag missing or tag not assigned.

The application has one or more messages
that has bit triggers enabled; however the Bit
Trigger Tag is undefined for the Application.

Change all message to value triggers or use
the Terminal Setup/Control Tags dialog to
define a Bit Trigger for the Application.

Chain-To-Message number greater than the
maximum allowed.

The message is chained to a non-existent
message.

Use Chain control on the Message Editor
Table View to disable the chain or alter the
“To” message number to select a different
existing message.

ББББББББББББ

Б

ББББББББББ

Б

ББББББББББББ

Checking Msg [number] for unsupported
features.

БББББББББББ

Б

БББББББББ

Б

БББББББББББ

ББББББББББББ

Б

ББББББББББ

Б

ББББББББББББ

Display variable storage size is greater than
100 characters. Reduce the tag sizes of
display variables.

The combined tag array sizes for the
embedded ASCII Variable Display variables in
the message exceed 100 characters.

Use the tag editor to reduce the array size of
the tags assigned to the embedded ASCII
Variable Display variables in the message.

Duplicate Message Number within
Application.

The message number for all messages in an
Application are not unique.

Renumber or delete the offending message to
insure that message numbers are unique.

Duplicate RTC Date Variables within
message.

The message has more than one embedded
Date variable. One is permitted per message.

Remove all but one Date variable.

Duplicate RTC Time Variables within
message.

The message has more than one embedded
Time variable. One is permitted per message.

Remove all but one Time variable.