Chapter 1 Prepare the Kinetix 350 Drive Hardware
Disable the Safe Torque-off Feature
The safe torque-off feature is used in applications used in safety conditions. This feature safely 
removes power from the gate firing circuits of the drives output power devices (IGBTs). The 
feature is enabled by default when the Kinetix 350 drive ships from the factory.
If your application, for example, the one used in this quick start, does not require the use of safety 
options, you disable the safe torque-off feature. You use jumper wires, as shown, to disable the 
safe torque-off feature. The tasks in this quick start are not completed in an environment that 
includes safety conditions. You can disable the safe torque-off feature.
Complete these steps to disable the safe torque-off feature.
1.
Remove the STO connector from 
the drive.
2.
Install STO Motion-allowed 
jumpers at the termination points 
as shown.
3.
Insert the STO connector into the 
bottom of the drive.
IMPORTANT
For more information about 
using the safe torque-off 
feature in an environment 
that includes safety 
conditions, see the Kinetix 
350 Single-axis EtherNet/IP 
Servo Drive User Manual, 
publication 