Chapter 1 Prepare the Kinetix 350 Drive Hardware

Wire the Motor Power Connector

This publication uses a 2090-CPWM7DF-16AA03 standard power cable with SpeedTec DIN
connector type 923 to wire power from the 2097-V31PR2-LM drive to the motor.

Complete these steps to wire the power cable to the MP connector.

1.

Remove the MP connector from the bottom of the drive.

2.

Remove approximately 7 mm
(0.28 in.) insulation from four
2.5 mm

2

(14 AWG)

copper wires.

3.

Insert the wires into the
appropriate connector positions
according to the following table.

4.

Insert the MP connector into the module as shown above.

5.

Connect the other end of the 2090-CPWM7DF-16AA03 cable to the motor.

MP-Series Servo
Motor Wire

Terminal

Green/
yellow

PE

W/Blue

W

V/Black

V

U/Brown

U

W

V

U

PE

W

V

U

Bottom View of Drive