Add a Kinetix 350 Drive to an RSLogix 5000 Project Chapter 2

Axis

Off

One of the following conditions exists:
Off
Initialization is in process - Bus not operating
Shutdown is in process - Bus not operating
Pre-charge is in process - Bus not operating

Flashing red/green

Self-test (power-up diagnostics) in process

Flashing green

One of the following conditions exists:
Initialization is in process- Bus is operating
Axis is stopped.

Flashing amber

One of the following conditions exists:
Shutdown is in process - Bus is operating
Start is inhibited.

Steady green

One of the following conditions exists:
Axis is stopping.
Axis is starting.
Axis is running.
Axis is testing.

Flashing red

One of the following conditions exists:
Axis is aborting.
Axis experienced a major fault.

Steady red

One of the following conditions exists:
Axis is aborting.
Axis experienced a major fault.

Table 2 - Drive Status Indicators

Status Indicator

Condition

Status