Wire the motor feedback connector, Wire the motor, Feedback connector – Rockwell Automation Logix5000 Control System: Connect Kinetix 350 Drives over an EtherNet/IP Network Quick Start User Manual

Page 26

Advertising
background image

26

Rockwell Automation Publication IASIMP-QS032A-EN-P - March 2012

Chapter 1 Prepare the Kinetix 350 Drive Hardware

Wire the Motor Feedback Connector

This publication describes how to use a
2090-CFBM7DD-CEAA03 standard
feedback cable with SpeedTec DIN
connector type 623 to wire feedback
from the motor to the drive.

Complete these steps to wire the
MF connector.

1.

Plug the premolded feedback cable
into the MF connector on the
front of the drive.

2.

Tighten the fastening screws at the top and bottom of the motor feedback connector to
secure the connection.

3.

Connect the other end of the cable to the MPL-A310P-MJ72AA motor.

Advertising