Test the axis – Rockwell Automation Logix5000 Control System: Connect Kinetix 350 Drives over an EtherNet/IP Network Quick Start User Manual

Page 44

Advertising
background image

44

Rockwell Automation Publication IASIMP-QS032A-EN-P - March 2012

Chapter 2 Add a Kinetix 350 Drive to an RSLogix 5000 Project

Test the Axis

Complete these steps to test the axes.

1.

Remove the load from Axis_1.

2.

Right-click Axis_1 in your Motion
Group folder and choose
Properties.

The Axis Properties dialog box
opens.

3.

Click the Hookup Tests category.

4.

Click the Motor and Feedback tab.

5.

Type 2.0 as the number of
revolutions for the Motor and
Feedback test.

The Motor and Feedback test
verifies the motor power and
feedback connections are wired
correctly as you command the
motor to rotate.

6.

Apply 24V DC power to the 2097-V31PR2-LM drive’s IOD connector.

7.

Click Start.

IMPORTANT

This section assumes that your 2097-V31PR2-LM drive’s status indicators show that drive is
operating as expected.

If the status indicators do not reflect a fully operational drive state, as described in

Table 2 on

page 42

, use the table to address any issues with regard to the drive’s stater before proceeding with

this section.