Configure the motion group, Configure the, Motion group – Rockwell Automation Logix5000 Control System: Connect Kinetix 350 Drives over an EtherNet/IP Network Quick Start User Manual

Page 37

Advertising
background image

Rockwell Automation Publication IASIMP-QS032A-EN-P - March 2012

37

Add a Kinetix 350 Drive to an RSLogix 5000 Project Chapter 2

13.

Type the axis Name.

AXIS_CIP_DRIVE is the default
Data Type.

14.

Change the Scope to your
controller project.

In this case, the Scope is
Kinetix_350_project.

15.

Click Create and Close.

16.

When the Module Properties dialog box appears, the new axis appears in the Axis 1: field.

17.

Click OK.

Configure the Motion Group

Complete these steps to configure the motion group.

1.

Right-click Motion Groups in the
Controller Organizer and choose
New Motion Group.

The New Tag dialog box opens.