The ratio of 1:20 is the same for all durations of 150%. When operating
continuous at 100%, if the load increases to 150% for 1 second the load must
then return to 100% for 20 seconds before another step to 150%

Motor Overload
Protection

FLA%

Cold Trip
Time

Hot Trip
Time

FLA%

Cold Trip
Time

Hot Trip
Time

FLA%

Cold Trip
Time

Hot Trip
Time

105

6320

5995

155

160

50

205

66

14

110

1794

1500

160

142

42

210

62

12

115

934

667

165

128

36

215

58

11

120

619

375

170

115

31

220

54

10

125

456

240

175

105

27

225

51

10

130

357

167

180

96

23

230

48

9

135

291

122

185

88

21

235

46

8

140

244

94

190

82

19

240

44

8

145

209

74

195

76

17

245

41

7

150

180

60

200

70

15

250

39

7

20 Minutes

1 Minute

1 Minute

100%

150%

PowerFlex 70

PowerFlex 70:

Class 10 motor overload protection according to NEC article 430
and motor over-temperature protection according to NEC article
430.126 (A)(2). UL 508C File E59272.

PowerFlex 700

Frames 0…6 Standard Control:

Frames 0…6 Vector Control:

Frames 7…10 Vector Control:

PowerFlex 700 drives with standard control, identified by an N,
A, or B in position 15 of the catalog number, only provide Class
10 motor overload protection according to NEC article 430. They
do not provide speed sensitive overload protection, thermal
memory retention and motor over-temperature sensing
according to NEC article 430.126 (A) (2). If such protection is
needed in the end-use product, it must be provided by
additional means.
PowerFlex 700 drives with vector control, identified by a C or D in
position 15 of the catalog number, provide class 10 motor
overload protection according to NEC article 430 and motor
over-temperature protection according to NEC article 430.126
(A) (2). UL 508C File E59272.
Class 10 motor overload protection according to NEC article 430
and motor over-temperature protection according to NEC article
430.126 (A)(2). UL 508C File E59272.