Start-Up

180

Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013

Figure 42 PowerFlex 70 & 700 Standard Control Option Startup (2)

StartUp
2. Motr Dat/Ramp

Enter value for

Motor NP Power

123.4 kW
xxx.x <> yyy.y

StartUp
2. Motr Dat/Ramp

Enter value for

Motor NP Volts

123.4 Volt
xxx.x <> yyy.y

StartUp
2. Motr Dat/Ramp

Enter value for

Motor NP FLA

+456.78 Amps
xxx.xx <> yyy.yy

StartUp
2. Motr Dat/Ramp

Enter value for

Motor NP RPM

+456 RPM
xxx <> yyy

StartUp
2. Motr Dat/Ramp

Enter value for

Motor NP Hertz

60.0 Hz
x.x <> y.y

StartUp
2. Motr Dat/Ramp

Enter choice for

Mtr NP Pwr Units

Go to 0-1 (3)

StartUp
2. Motr Dat/Ramp

Enter value for

Accel Time 1

6.0 Secs
0.0 < 60.0 secs

StartUp
2. Motr Dat/Ramp

Enter value for

Decel Time 1

6.0 Secs
0.0 < 60.0 secs

StartUp
2. Motr Dat/Ramp

Enter value for

S Curve %

0 %
0 < 100 %

StartUp
2. Motr Dat/Ramp

Use motor name-
plate data and
required ramp
times for the
following steps.

Basic Start Up (Motor Data/Ramp)

2-0

Enter

2-1

2-2

Enter

Enter

2-3

Enter

2-4

Enter

2-5

2-6

Enter

2-11

Enter

2-12

2-13

Enter

Enter

StartUp
2. Motr Dat/Ramp

Enter choice for

Stop Mode A

2-7

Enter

Enter

StartUp
2. Motr Dat/Ramp

Enter value for

DC Brake Level

1.0 Amps
0.0 < 30.0 Amps

2-8

Yes

StartUp
2. Motr Dat/Ramp

Enter value for

DC BrakeTime

1.0 Secs
0.0 < 90.0 Secs

2-9

Enter

No

StartUp
2. Motr Dat/Ramp

Enter choice for
DB Resistor Type

None
Internal
External

2-10

Enter

Enter

Backup

Backup

None - Bus Reg Mode A = Adj Freq.
Intenal - Bus Reg Mode A = Both, DB 1st.
External - Bus Reg Mode A = Both, DB 1st.

Yes

No

Backup

Stop Mode A

= "DC Brake" or

"Ramp to

Hold"?

Stop Mode A

= "DC

Brake"?