User sets – Rockwell Automation 20B PowerFlex 70, PowerFlex 700 Reference Manual User Manual

Page 206

Advertising
background image

User Sets

206

Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013

User Sets

After a drive has been configured for a given application the user can store a copy
of all of the parameter settings in a specific EEPROM area known as a “User Set.”
Up to 3 User Sets can be stored in the drives memory to be used for backup, batch
“switching” or other needs. All parameter information is stored. The user can
then recall this data to the active drive operating memory as needed. Each User
Set can also be identified with a programmable name, selected by the user for
clarity.

Two operations are available to manage User Sets, “Save To User Set” and
“Restore From User Set.” The user selects 1, 2, or 3 as the area in which to store
data. After data is successfully transferred, “Save User Set” returns to a value of 0.
To copy a given area back into the active EEprom memory, the user selects Set 1,
2, or 3 for “Restore User Set.” After data is successfully transferred, “Restore User
Set” returns to a value of 0. When shipped from the factory all user sets have the
same factory default values. Reset Defaults does not effect the contents of User
Sets.

Important:

User Sets can only be transferred via the HIM. No provisions exist
for control via digital I/O or communications module.

Figure 61 User Sets

Drive Rating & Motor

Parameters

1

2

3

Non Drive Rating & Motor

Parameters

1

2

3

User Set 1

User Set 3

User Set 2

Flash Memory

Flash Memory

Active EE

Reset Defaults

Reset

Active EE

Load

Application

Set

Application Set

RestoreUserSet

SaveUserSet

Save

User set

Restore

User set

400V

Default Data

Factory

Default Data

480V

Default Data

PowerBoard

EEprom

Advertising