Digital Inputs

Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013

71

Digital Input Configuration

Inputs are configured for the required function by setting a [Digital Inx Sel]
parameter (one for each input). These parameters cannot be changed while the
drive is running.

PowerFlex 700 Digital Input Selection

INPUTS & OUTPUTS

Digital Inputs

361
362
363
364
365
366

[Digital In1 Sel]
[Digital In2 Sel]
[Digital In3 Sel]
[Digital In4 Sel]
[Digital In5 Sel]
[Digital In6 Sel]

(11)

Selects the function for the digital inputs.

(1)

Speed Select Inputs.

To access Preset Speed 1, set [Speed
Ref x Sel] to “Preset Speed 1”.

Type 2 Alarms - Some digital input
programming may cause conflicts
that will result in a Type 2 alarm.
Example: [Digital In1 Sel] set to “5,
Start” in 3-wire control and [Digital
In2 Sel] set to 7 “Run” in2-wire.

Refer to User Manual for information
on resolving this type of conflict.

(2)

Vector Control Option Only.

Default:
Default:
Default:
Default:
Default:
Default:

Options:

4
5
18
15
16
17

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15-17
18
19
20
21
22
23
24
25
26
27
28
29
30
31-33
34

“Stop – CF”
“Start”
“Auto/ Manual”
“Speed Sel 1”
“Speed Sel 2”
“Speed Sel 3”

“Not Used”
“Enable”

(8)(10)

“Clear Faults”(CF)

(4)

“Aux Fault”
“Stop – CF”

(10)

“Start”

(5)(9)

“Fwd/ Reverse”

(5)

“Run”

(6)(10)

“Run Forward”

(6)

“Run Reverse”

(6)

“Jog”

(5)

“Jog1”

(2)(5)

“Jog Forward”

(6)

“Jog Reverse”

(6)

“Stop Mode B”
“Bus Reg Md B”
“Speed Sel 1-3”

(1)

“Auto/ Manual”

(7)

“Local”
“Acc2 & Dec2”
“Accel 2”
“Decel 2”
“MOP Inc”
“MOP Dec”
“Excl Link”
“PI Enable”
“PI Hold”
“PI Reset”
“Pwr Loss Lvl”
“Precharge En”
“Spd/Trq Sel1-3”

(2,3)

“Jog 2”

(2)

100

156
162

096

140

194

380
384
388
124

(4)

When [Digital Inx Sel] is set to option 2 “Clear Faults” the Stop button cannot be
used to clear a fault condition.

(5)

Typical 3-Wire Inputs - Requires that only 3-wire functions are chosen.
Including 2-wire selections will cause a type 2 alarm.

(6)

Typical 2-Wire Inputs - Requires that only 2-wire functions are chosen. Includ-
ing 3-wire selections will cause a type 2 alarm. See User Manual for conflicts.

(7)

Auto/Manual - Refer to User Manual for details.

(8)

Opening an “Enable” input will cause the motor to coast-to-stop, ignoring any
programmed Stop modes.

(9)

A “Dig In ConflictB” alarm will occur if a “Start” input is programmed without a
“Stop” input.

(10)

Refer to the Sleep-Wake Mode Attention statement on User Manual.

(11)

A dedicated hardware enable input is available via a jumper selection. Refer to
User Manual for further information.

3

2

1

Auto Reference Source

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Reference A
Reference B
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Preset Speed 6
Preset Speed 7

(3)

3

2

1

Spd/Trq Mode

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Zero Torque
Spd Reg
Torque Reg
Min Spd/Trq
Max Spd/Trq
Sum Spd/Trq
Absolute
Zero Trq