Figure 46 PowerFlex 70 & 700 Standard Control Option Startup (6)

Basic Start Up (Start,Stop,I/O)

StartUp
A. Dig Inputs

Make a selection

<Digital Input 1>
Digital Input 2
Digital Input 3
Digital Input 4
Digital Input 5
Digital Input 6
Done

6-0

6-17

Go to 6-1 (B)

StartUp
A. Dig Inputs

Enter choice for

Digital In1 Sel

StartUp
A. Dig Inputs

Enter choice for

Digital In2 Sel

6-18

6-19

StartUp
A. Dig Inputs

Enter choice for

Digital In3 Sel

6-20

StartUp
A. Dig Inputs

Enter choice for

Digital In4 Sel

6-21

StartUp
A. Dig Inputs

Enter choice for

Digital In5 Sel

6-22

StartUp
A. Dig Inputs

Enter choice for

Digital In6 Sel

6-23

Digital In 1

Digital In 2

Digital In 3

Digital In 4

Digital In 5

Digital In 6

StartUp
A. Dig Inputs

Make a selection

<Easy Configure>
Custom Configure

6-2

DigIn 5,6 = MOP

Inc, Dec?

StartUp
A. Dig Inputs

Digital Inputs
1-4 will be set
to defaults.

6-3

StartUp
A. Dig Inputs

Digital Inputs
1-6 will be set
to defaults.

6-4

StartUp
A. Dig Inputs

Digital Input 3
will be set to Fwd/
Reverse.

6-14

StartUp
A. Dig Inputs

Digital Input 1
will be set to
Run Forward.

6-12

StartUp
A. Dig Inputs

Digital Input 2
will be set to
Run Reverse.

6-13

StartUp
A. Dig Inputs

Digital Input 1
will be set to
Not Used.

6-7

StartUp
A. Dig Inputs

Digital Input 2
will be set to
Run/Stop.

6-8

Custom Configure

A. Dig Inputs

Easy Configure

No

Yes

Enter

Enter

Dir Mode =

Reverse

Disable?

StartUp
A. Dig Inputs

Enter choice for
Control Method

<3-wire>
2-wire

6-6

No

Yes

Dir Mode =

Bipolar?

2-wire

3-wire

Go to 6-1 (B)

Yes

StartUp
A. Dig Inputs

Is reverse
required from
digital inputs?

<Yes>
No

6-5

No

StartUp
A. Dig Inputs

Enter choice for
Control Method

<3-wire>
2-wire

6-11

Yes

No

3-wire

2-wire

Enter

Enter

Enter

Enter

Enter

Done

Backup

StartUp
A. Dig Inputs

Digital Input 1
will be set to
Stop.

6-9

StartUp
A. Dig Inputs

Digital Input 2
will be set to
Start.

6-10

Enter

StartUp
A. Dig Inputs

Digital Input 1
will be set to
Stop.

6-15

StartUp
A. Dig Inputs

Digital Input 2
will be set to
Start.

6-16

Enter

Enter

Enter

StartUp
6. Strt,Stop,I/O

This section
defines I/O fun-
ctions including
start and stop
from digital ins

StartUp
6. Strt,Stop,I/O

Complete these
steps in order:

<A. Dig Inputs>
B. Dig Outputs
C. Anlg Outputs
D. Done

Enter

B. Dig

Outputs

Go to 6-24

Go to 6-29

6-1

D. Done

Go to 0-1 (7)

C. Anlg

Outputs

Backup

Backup

Enter/

Backup