Start-Up

Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013

189

Figure 51 PowerFlex 700 Vector Control Option Startup (3)

Flux Vector Start Up (Motor Tests)

Start-Up
3. Motor Tests
This section
optimizes motor
performance and
tests for proper
direction.

3-0

Go to 0-1 (4.Speed

Limits)

Start-Up
A. Directn Test
Press Jog or Start
to begin.

Start-Up
A. Directn Test
Motor rotation
correct for
application?
<Yes>
No

Start/Jog

(disallow Start/Jog)

Start-Up
B. AutoTune
Make a selectioon
Static Tune
<Rotate Tune>

Start-Up
A. Directn Test
Test complete.
Press <ENTER>

Start-Up
B. Auto Tune.
Static Tune will
energize motor
with no shaft
rotation. Press
START to begin.

Start-Up
B. Auto Tune
Caution: Rotate
Tune will cause
shaft rotation.
Press START to
begin.

Start-Up
B. Auto Tune
Test complete.
Press <ENTER>

Start-Up
B. Auto Tune
Executing test.
Please wait...

Rotate Tune

3-3

D. Done

If NO..

(stops

drive)

If YES & positive
encoder counts..

(stops drive)

Start (disallow

Start/Jog)

Enter/

Backup

Start-Up
3. Motor Tests
Test aborted due
to user stop.
Clear fault to
continue.

3-8

3-9

3-10

3-11

3-6

3-7

3-5

3-12

3-4

Start-Up
3. Motor Tests
Test aborted!
Clear the fault.
Check motor data
settings. Verify
load is removed.

3-13

Fault

(stops drive)

Start-Up
3. Motor Tests
Complete these
steps in order:
<A. Directn Test>
B. Auto Tune
C. Inertia Test
D. Done

3-1

B. Auto Tune

Enter

Start-Up
B. AutoTune
IMPORTANT!!
Use Rotate Tune
if no load/low
friction/Flux
Vector mode.
Else use Static
Tune. For
special applic-
ations, see ref-
erence maual.

3-2

Start (disallow

Start/Jog)

Stop or Esc

(stops drive)

Backup

Note: Set #61

(Autotune) to '2' or

'1' depending on

selection

Note: States 3-8

& 3-9 allow Start.

Start-Up
3. Motor Tests
Cannot start due
to open Stop
input or other
[Start Inhibits]
Press Enter.

3-14

Enter

Note:
- Fix Jog/Reference to
5 Hz.
- State 3-4 allows
Start/Jog

Start Inhibit

param != 0

Yes

Start Inhibit

param != 0

Yes

No

Start-Up
C. Inertia Test
Enter value for
Speed Desired BW
60.0 RPM
xxx.x <> yyy.y

3-15

Note:
- The Motor Tests are NOT executed while in V/Hz mode.

Start-Up
B. Auto Tune
Enter value for
Autotune Torque
6.0 %
xxx.x <> yyy.y

3-16

Start-Up
A. Directn Test
Power down and
swap encoder
leads.

3-17

If YES &
negative

encoder

counts..

(stops

drive)

Go to State 3-4

Static

Tune

Start-Up
C. Inertia Test
Caution:Inertia
Test causes
shaft rotation.
<START> to begin

Rotate/Static Tune

complete

(stops drive)

Start-Up
C. Inertia Test
Connect load to
motor for
Inertia Test.

Start-Up
C. Inertia Test
Executing test.
Please wait...

Start-Up
C.Inertia Test
V/Hz Control
does not require
an Inertia Test.

3-21

3-18

3-19

3-20

Fault

(stops drive)

Stop or ESC
(stops drive)

FOC?

No

Yes

No

Start-Up
3. Motor Tests
Select source of
Start/Stop
<Digital Inputs>
Local HIM-Port1
Remote HIM-Port2

3-22

If Digital Inputs:- Set
#361/2 to START/STOP resp.
If Local HIM:- Set
#361/2 to Not Used &
#90 to 18

Start-Up
A. Directn Test
Startup will
automatically
reverse the
MotorLeads.

Go to 3-1

Start-Up
C. Inertia Test
Test complete.
Press <ENTER>

Go to 3-1

3-23

C. Inertia Test

FOC

Mode?

No

Start-Up
B. Auto Tune
Rotate Tune
done. Press
ENTER to con-
tinue with
Inertia Test.

Yes

Go to State 3-18

3-24

Motor

Cntl

Sel?

FOC

Start-Up
C.Inertia Test
Sensrls Vector
does not require
an Inertia Test.

SV

3-25

Go to 3-1

V/Hz

Direction

Test