Advanced Tuning

Rockwell Automation Publication PFLEX-RM001H-EN-P - June 2013

13

UT

IL

IT

Y

D

ia

g-M

oto

r C

n

tl

509 [Lo Freq Reg KpId]

This proportional gain adjusts the output voltage at very
low frequency in response to the reactive, or d-axis,
motor current. A larger value increases the output
voltage change.

Default:

Min/Max:
Units:

64

0/32767
1

510 [Lo Freq Reg KpIq]

The proportional gain adjusts the output voltage at very
low frequency in response to the active, or q-axis, motor
current. A larger value increases the output voltage
change.

Default:

Min/Max:
Units:

64

0/32767
1

511 [Ki Cur Reg]

This integral gain adjusts the output voltage in response
to the q and d axis motor currents. A larger value
increases the output voltage change.

Default:

Min/Max:
Units:

44

0/32767
1

512 [Kp Cur Reg]

This proportional gain adjusts the output voltage in
response to the q and d axis motor currents. A larger
value increases the output voltage change.

Default:

Min/Max:
Units:

1600

0/32767
1

523 [Bus Utilization]

This value sets the drive output voltage limit as a
percentage of the fundamental output voltage when
operating in 6 step mode. Values above 95% increase
harmonic content and jeopardize control stability. This
output voltage limit is strictly a function of input line and
resulting bus voltage.

Default:

Min/Max:
Units:

95.0%

85.0/100.0%
0.1%

524 [PWM Type Sel]

Allows selection of the active PWM type. A value of 0 is
default, and results in a change of PWM method at
approximately 2/3 of rated motor frequency. If this is
unacceptable for harmonic or audible reasons, a value of
1 disables the change.

Default:

Min/Max:
Units:

0

0/1
1

536 [Ki Flux Braking]

Proportional gain for the Flux Regulator

Default:

Min/Max:
Units:

100

0/32767
1

537 [Kp Flux Braking]

Integral gain for the Flux Regulator

Default:

Min/Max:
Units:

500

0/32767
1

538 [Rec Delay Time]

TBD

Default:

Min/Max:
Units:

1000

1/30000
1

Di

ag

-D

AC

s

513 [PWM DAC Enable]

Reserved. Do Not Adjust

Default:

Min/Max:
Units:

0

0/1
1

514
515
516
517

[DAC47-A]
[DAC47-B]
[DAC47-C]
[DAC47-D]

Reserved. Do Not Adjust

Default:

Min/Max:
Units:

0

0/7432
1

518 [Host DAC Enable]

Reserved. Do Not Adjust

Default:

Min/Max:
Units:

0

0/1
1

519
520
521
522

[DAC55-A]
[DAC55-B]
[DAC55-C]
[DAC55-D]

Reserved. Do Not Adjust

Default:

Min/Max:
Units:

0

0/7432
1

Fil

e

Gr

oup

No

.

Parameter Name & Description

Values

Rela

ted

Advertising
This manual is related to the following products: