Appendix j, D-c amp rating parameter precautions – Rockwell Automation SD3000 Drive Configuration, Programming User Manual
Page 111
![background image](/manuals/581715/111/background.png)
Appendix J
D-C Amp Rating Parameter Precautions
Normally, the D-C Amp rating parameter is automatically filled in by the system after the user selects a Power
Module part number from the list. However, if you are filling in your own values because you are using a
Power Module that is not on the list, you must take the following precaution when filling in the D-C Amp rating
parameter.
Because of internal design considerations, the following four D-C Amp ratings are interpreted by the PMI
operating system to correspond only to the 2-15 HP and 16-60 HP Power Modules listed below. These four
D-C Amp ratings must NOT be used for other Power Modules or the voltage feedback sensed by the PMI
operating system will be incorrect.
For these D-C Amp Ratings
25A and 27A
Use Only These Power Modules
8036004 SRx or 80361 O-l SRx
1 OOA and 125A
803601-I SRx or 80361 I-l SRx
J-l