Appendix j, D-c amp rating parameter precautions – Rockwell Automation SD3000 Drive Configuration, Programming User Manual

Page 111

Advertising
background image

Appendix J

D-C Amp Rating Parameter Precautions

Normally, the D-C Amp rating parameter is automatically filled in by the system after the user selects a Power
Module part number from the list. However, if you are filling in your own values because you are using a
Power Module that is not on the list, you must take the following precaution when filling in the D-C Amp rating

parameter.

Because of internal design considerations, the following four D-C Amp ratings are interpreted by the PMI

operating system to correspond only to the 2-15 HP and 16-60 HP Power Modules listed below. These four

D-C Amp ratings must NOT be used for other Power Modules or the voltage feedback sensed by the PMI

operating system will be incorrect.

For these D-C Amp Ratings

25A and 27A

Use Only These Power Modules

8036004 SRx or 80361 O-l SRx

1 OOA and 125A

803601-I SRx or 80361 I-l SRx

J-l