87/1087

PMI A/B Format Error Count Register

Hex Value:

N/A

Sug. Var. Name:

N/A

Range:

N/A

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Description:

This register contains the number of messages with format errors received by the Drive

A and Drive B PMls.

88/1 088

UDC Module Potts A/B Fiber-Optic Link Status Register

Hex Value:

N/A

Sug. Var. Name:

N/A

Range:

N/A

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Description:

This register indicates the current operating state of fiber-optic links A and B. The lower

byte (bits O-7) indicates the actual link status while the upper byte (bits 8-15) shows whether the
communication taking place is synchronized or not.

l

If the lower byte is equal to (xx01 H), the UDC module is waiting for a request from the PMI for an
operating system.

l

If the lower byte is equal to (xx02H), the UDC module is downloading an operating system to the
PMI.

l

If the lower byte is equal to (xx03H), the UDC module and the PMI are exchanging data.

l

If the lower byte is equal to (xx06H), the external loopback test is being conducted on the fiber-optic
link.

l

If the upper byte is equal to (01xxH), the communication between the UDC module and the PMI is
synchronized.

l

If the upper byte is equal to (02xxH), the communication between the UDC module and the PMI is
unsynchronized.

89/1 089

UDC Module Ports A/B Transmitted Message Count Register

Hex Value:

N/A

Sug. Var. Name:

N/A

Range:

N/A

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Description:

This register contains the number of messages transmitted by the UDC module on Port

A and Port B.