Armature PM Data

0

Field PM Data

0

Meter Port Selection

Speed Feedback Type

No Speed Feedback

0

Resolver

Analog

Resolver Type

None

xl

x 2

x5

Figure 2.6 - Speed Feedback Parameter Entry Screen With An Analog Tachometer Selected

Speed Feedback Tvpe Selections

W A R N I N G

THE USER MUST ENSURE THAT THE CORRECT FEEDBACK TYPE HAS BEEN SELECTED DURING
CONFIGURATION. IF “NO SPEED FEEDBACK” HAS BEEN SELECTED, THE USER MUST PROVIDE
A N I N D E P E N D E N T M E T H O D O F O F D E T E C T I N G O V E R S P E E D , O T H E R W I S E , A F E E D B A C K L O S S
WILL NOT BE DETECTED, RESULTING IN MOTOR OVERSPEED. FAILURE TO OBSERVE THIS

PRECAUTION COULD RESULT IN BODILY INJURYAND IN DAMAGETO, OR DESTRUCTION OF, THE
EQUIPMENT.

l

No Speed Feedback

If you select No Speed Feedback, which is the default, you do not have to enter Motor Base Speed,

Overspeed Trip Point, or Tach Volts at Over Speed Trip, however, you can select a resolver for

positioning purposes.

Note that if you select No Speed Feedback, the PMI Processor will not perform the Tach Loss and
Over Speed Diagnostics. You must provide an independent method of detecting motor overspeed.
Note also that automatic field weakening will be disabled if you select No Speed Feedback. Refer to
register 100/1 00, bit 11 for more information. Note that when a speed feedback device is used,
overspeed detection is active during auto-tuning.

l

Resolver

If you select Resolver, you must enter the Resolver Type.

l

Analog Tach

If you select Analog Tach, you must enter the Tach Volts at Overspeed Trip Point.

2-9