Rockwell Automation SD3000 Drive Configuration, Programming User Manual
Page 61

1 0 0 0
UDC Test Switch Inputs Register (Continued)
Bit: 2
Hex Value: 0004H
Sug. Var. Name:
SWIT_DN@
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Description:
The Switch Down Input bit is on when the switch is in the down position.
Bit: 8
Hex Value:
01 00H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED: OS
OK on the UDC module
Description:
Status of the Operating System OK LED on the UDC module (0 = Off; 1 = On).
Bit: 9
Hex Value: 0200H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
COMM A OK on the UDC module
Description:
Status of the COMM A OK LED on the UDC module (0 = Off; 1 = On).
Bit:
10
Hex Value: 0400H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
DRV A FLT on the UDC module
Description:
Status of the Drive A Fault LED on the UDC module (0 = Off; 1 = On).
Bit:
11
Hex Value: 0800H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
COMM B OK on the UDC module
Description:
Status of the COMM B OK LED on the UDC module (0 = Off; 1 = On).
Bit: 12
Hex Value: 1
000H
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read only
UDC Error Code:
N/A
LED:
DRV B FLT on the UDC module
Description:
Status of the Drive B Fault LED on the UDC module (0 = Off; 1 = On).
3-41