4 meter port selection screen – Rockwell Automation SD3000 Drive Configuration, Programming User Manual

Page 18

Advertising
background image

l

Motor Base Speed (RPM)

Speed Safety Data Selections

Enter the motor’s base speed. This value is the motor’s top operating speed under full field and is

the speed when field weakening begins. This value is found on the motor’s nameplate and can

range from 0 to 3600 RPM.

l

Over Speed Trip (RPM)

Enter the overspeed trip point. This is the limit to be used for overspeed detection and can range

from 0 to 5000 RPM. When an analog tachometer is used, this value is used to scale the analog

voltage into RPM. A typical value is 110% of gear-in speed.

l

Tach Volts at Over Speed Trip

Enter the tachometer voltage that will be present when the motor is turning at the overspeed trip

point RPM. Enter the value as x.xx. The value can range from 5 to 9.75 volts.

l

None

Resolver Type Selections

Select this option if a resolver is not being used.

. X1, X2, X5

If a resolver is being used, select which type it is: either Xl, X2, or X5.

2.2.4 Meter Port Selection Screen

The Meter Port Selection parameter screen allows you to enter specific information about what
variables are to be output on the four PMI D/A channels (the four “meter” ports on the PMI Processor

module). See figure

2.7.

Meter Port

:

Armature

Current

Feedback (Counts)

,

Armature Current Reference

00)

5.00 Units/Volt

50.0 Units at 0 V

Meter

Armature

Current Feedback

0)

Value

l

o

Value

200.00 Units/Volt

2000.0

Units at 0 V

Figure 2.7 - Meter Port Selection Entry Screen