Figure 2.8 shows the values that can be displayed on the PMI meter ports. These values are
described in detail in chapter 3. You must enter a Minimum Value and a Maximum Value for each
selection except for those marked as Port Not Used. The Minimum Value is the value at which to
output -1 0V The Maximum Value is the value at which to output + 1 OV. The system software then
places the units per volt on the screen based on the Minimum/Maximum Values. The Minimum Value
must not be less than -32768. The Maximum Value must not be greater than 32767. The Minimum

Value must be less than the Maximum Value. Note that the PMI meter ports have 8-bit resolution and

are updated on the average every 1 .O millisecond. Refer to the Power Module Interface Rack
instruction manual for more information about the PMI meter ports. Refer to section 3.6.2.1 for
information about resolution of data.

l

Port Not Used

l

Armature Current Reference (Counts) (4095 = current limit)

l

Armature Current Feedback (Counts) (4095 = current limit)

l

Armature Current Feedback (Amps x 10)

l

Armature Voltage (Volts)

l

Armature Maximum Firing Angle Sec)

l

Armature Firing Angle Sec)

l

Armature Minimum Firing Angle Sec)

l

Field Current Reference (Counts) (4095 = current limit)

l

Field Current Feedback (Counts) (4095 = current limit)

l

Field Current Feedback (Amps x 100)

l

Field Voltage (Volts)

l

Field Maximum Firing Angle Sec)

l

Field Firing Angle Sec)

l

Field Minimum Firing Angle Sec)

l

Counter EMF Voltage (Volts)

l

A-C RMS Line Voltage (Volts)

l

User Analog Input (Counts) (- 2048 to + 2047 = +1 -10V)*

l

Speed Feedback (RPM)

l

Application Data (Units) **

l

Rail Port 0 Channel 0 (Counts)

l

Rail Port 0 Channel 1 (Counts)

l

Rail Port 0 Channel 2 (Counts)

l

Rail Port 0 Channel 3 (Counts)

l

Rail Port 1 Channel 0 (Counts)

l

Rail Port 1 Channel 1 (Counts)

l

Rail Port 1 Channel 2 (Counts)

l

Rail Port 1 Channel 3 (Counts)

* Analog input from the Resolver and Drive l/O module. Refer to register 214/1 214 for more information.

** Refer to register 106/1 106 for more information.

Figure 2.8 - PMI Meter Port Parameters - SD3000