SGR Diagnostic Register (Continued)

Bit: 3
Hex Value: 0008H
Sug. Var. Name: SCR_04@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 4 Fault (Forward Bridge)

Bit: 4
Hex Value: 001

OH

Sug. Var. Name:

SCR_05@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 5 Fault (Forward Bridge)

Bit: 5
Hex Value: 0020H
Sug. Var. Name: SCR_06@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 6 Fault (Forward Bridge)

Bit: 6

Hex Value: 0040H
Sug. Var. Name:

SCR_1 1@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 11 Fault (Reverse Bridge)

Bit: 7
Hex Value: 0080H

Sug. Var. Name:

SCR_1 2@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 12 Fault (Reverse Bridge)

Bit: 8
Hex Value:

01 OOH

Sug. Var. Name:

SCR_1 3@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 13 Fault (Reverse Bridge)

Bit: 9
Hex Value: 0200H
Sug. Var. Name:

SCR_1 4@

Range:

N/A

Access:

Read Only

UDG Error Code:

N/A

LED:

N/A

Description:

SCR 14 Fault (Reverse Bridge)