Rockwell Automation SD3000 Drive Configuration, Programming User Manual

Page 57

Advertising
background image

21 1/121 1 Field Minor Loop Feedback Register

Hex Value: N/A

Sug. Var. Name:

FML_FB%

Range: -32768

to

+32767

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The Field Minor Loop Feedback register displays the measured field current (DC Amps)

in counts. A value of 4095 is equal to 100% of the Motor Field Hot Amps value in the parameter entry
screen.

212/1 212 Field Current Feedback Register

Hex Value:

N/A

Sug. Var. Name:

FLD-IFB% (amps x 100)

Range: -32768

to +32767

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The Field Amps Feedback register displays the measured field current. The displayed

value is equal to the number of amps times 100. For example, 10.00 amps of field current would be
displayed as 1000. The current is measured to within a tenth of an amp.

213/1 213 Field Voltage Feed back Register

Hex Value:

N/A

Sug. Var. Name:

FLD_VFB% (DC Volts)

Range: -32768

to +32767

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The Field Voltage Feedback register displays the field voltage feedback value. A value

of 1 is equal to 1 volt. This voltage is calculated based on the AC line and field firing angle.

214/1 214 User Analog input Register

Hex Value:

N/A

Sug. Var. Name:

Al%

Range: -2048

(-10V) to +2047 (+10V)

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The User Analog Input register displays the measured user analog input value from the

Resolver Feedback connector on the Resolver & Drive l/O module. This value may be accessed

through the PMI meter ports.

215/1 215 Resolver Scan Position Register
Hex Value:

N/A

Sug. Var. Name:

RES_SCN_POS%

Range:

-32768 to 32767 corresponding to the resolver’s position

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The Resolver Scan Position register displays the electrical position of the resolver (if

used) at the beginning of the UDC task scan. This register is reset to zero at power-up.

216/1 216 Resolver Strobe Position Register

Hex Value:

N/A

Sug. Var. Name:

RES_STR_POS%

Range: -32768

to 32767 corresponding to the resolver’s position

Access:

Read Only

UDC Error Code:

N/A

LED:

N/A

Description:

The Resolver Strobe Position register displays the electrical position of the resolver at

the time a strobe signal is detected.

Advertising