5 ramping-down signals psd and msd, 6 in-position signal inp, Ramping-down signals psd and msd – ADLINK PCI-8134A User Manual

Page 34: In-position signal inp

Advertising
background image

24

Signal Connections

3.5

Ramping-down Signals PSD and MSD

There are two ramping-down

(Slow−Down) signals PSD and MSD for one

axis. The relative signal name, pin number and axis number are shown in
the following table.

CN2 Pin No

Signal Name

Axis

#

39

PSD1

40

MSD1

45

PSD2

46

MSD2

89

PSD3

90

MSD3

95

PSD4

96

MSD4

The signals connection and relative circuit diagram is shown in the following
diagram. Usually, limit switches are used to generate the slow

−down

signals to make motor operating in a slower speed. For more details of the
SD operation, please refer to section 4.3.1.

3.6

In-position Signal INP

The in-position signals INP from the servo motor driver indicate the
deviation error is zero, that is the servo position error is zero. The relative
signal name, pin number and axis number are shown in the following table.

EX+24V

I

f

=6mA Max.

Filter

Circuit

Motion ASIC

PSD
MSD

4.7K

EXGND

Inside PCI-8134/PCI-8134A

CN2

 Switch

Advertising