6 motion parameters control, 7 play key control, Motion parameters control – ADLINK PCI-8134A User Manual

Page 83: Play key control

Advertising
background image

Motion Creator

73

Manual Pulser Mode:

Press “Manual Pulser Move” button will enable motion controlled by hand
wheel pulser. Using this function, user can manually operate the axis thus
verify operation. The maximum moving velocity is limited as specified by
“Maximum Velocity”. Press “STOP” to end this mode.

Do remember to press “STOP” to end operation under this mode. Otherwise,
operations under other modes will be inhibited.

5.3.6

Motion Parameters Control

Use the Motion Parameters with the Operation Mode Control to command
motion.

• Starting Velocity: Specify the starting moving speed in pulses

per second.

• Maximum Velocity: Specify the maximum moving speed in

pulses per second.

• Acceleration: Specify the acceleration in pulses per second

square.

• Move delay: Specify time in mini seconds between movement.
• S curve Acc/dec Time: Specify time in mini second for S_curve

Movement.

5.3.7

Play Key Control

Use buttons in Play Key Control to begin or end operation.

: click button under this symbol to begin moving to Positions 2 in
Absolute Mode or moving forward in other modes.

: click button under this symbol to begin moving to Positions 1 in
Absolute Mode or moving backward in other modes.

: click button under this symbol to stop motion under any mode.
Note that this button is always in latch mode. Click again to
release “STOP” function.

Advertising