Function Library

81

@ Name

set_pls_outmode – Set the configuration for pulse command output.
set_pls_iptmode – Set the configuration for feedback pulse input.
set_cnt_src – Enable/Disable the external feedback pulse input

@ Description

set_pls_outmode:

Configure the output modes of command pulse. There are two modes for
command pulse output.

set_pls_iptmode:

Configure the input modes of external feedback pulse. There are four
types for feedback pulse input. Note that this function makes sense only
when cnt_src parameter in set_cnt_src() function is enabled.

set_cnt_src:

If external encoder feedback is available in the system, set the cnt_src
parameter in this function to Enabled state. Then internal 28-bit up/down
counter will count according configuration of set_pls_iptmode() function.
Or the counter will count the command pulse output.

@ Syntax

C/C++ (DOS, Windows)

U16 set_pls_outmode(I16 axis, I16 pls_outmode)
U16 set_pls_iptmode(I16 axis, I16 pls_iptmode)
U16 set_cnt_src(I16 axis, I16 cnt_src)

Visual Basic (Windows)

set_pls_outmode (ByVal axis As Long, ByVal pls_outmode

As Long) As Integer

set_pls_iptmode (ByVal axis As Long, ByVal pls_iptmode

As Long) As Integer

set_cnt_src (ByVal axis As Long, ByVal cnt_src As Long)

As Integer

@ Argument

axis:axis number designated to configure pulse

Input/Output.

pls_outmode: setting of command pulse output mode for

OUT and DIR pins.
pls_outmode=0, OUT/DIR type pulse output.
pls_outmode=1, CW/CCW type pulse output.

pls_iptmode: setting of encoder feedback pulse input

mode for EA and EB pins.

pls_iptmode=0, 1X AB phase type pulse input.

pls_iptmode=1, 2X AB phase type pulse input.

pls_iptmode=2, 4X AB phase type pulse input.