ManagementServer Element:

◦ ManagementServer element's value is the optional IP address of the management

ingest server. It is ignored in ShowVault software but is used in TMS software. The
purpose is to separate the management stream from the data stream. File browsing
and management communication uses the Management server, but all actual data is
transferred using the Server IP address.

SerialNumber Element:

◦ The SerialNumber element's value is the serial number of the ingest server in case

the server is a regular ShowVault system acting as an ingest server. This property is
ignored by the ShowVault software and is used in TMS software.

Sync Element:

◦ The Sync element's value indicates the system that the ingest server can be used for

dynamic data access (play ingest). Above properties can be re-defined under this
node. This new set of property will be used when dynamic data access is required. If
no property is re-defined, then the previous set is used.

Note: Only the communication data is subject to be re-defined (Server, Type, Share, User, and
Password). The identification properties will be ignored (Serial Number and Auditorium).

Filters Element:

◦ The Filters element's value lists the file to scan on the ingest server. The available

filters are PKG (Package), PKL (Packing List), KDM, DLM (License File), and SPL
(Show Playlist). If no filters are specified, then it will only scan for a PKL file (legacy
behavior).

◦ Example: <Filters>PKL, KDM, DLM</Filters> will scan ingest server and return the

list of available PKL, KDM, and DLM.