Drives insertion, General rules, Hdds shipment – Doremi ShowVault / IMB User Manual

Page 12: 4 drives insertion

Advertising
background image

____________________________________________________________________________________

SHV.OM.001293.DRM

Page 12 of 146

Version 1.5

Doremi Labs

1.4 Drives Insertion

1.4.1 General Rules

In all cases, do not insert or remove drives if the unit is powered on.

Drives are to be of the same make and model, and have the same capacity.

Doremi prohibits mixing SATA I drives with SATA II drives within the same RAID.

1.4.2 HDDs Shipment

Hard disk drives (HDDs) are shipped out of the chassis. In this case, insert them in to the server
before plugging in the power cables according to the procedure presented below:

Identify the label written on each HDD.

There will be one HDD with "A", one HDD with "B", and one HDD with "C" written on

them (Figure 1).

Figure 1

: HDD Label Location With “A” Label

For each HDD press on the blue button located on its front side in order to release the

gray handle.

Open the gray handle all the way until it clicks (Figure 2).

HDD Label

Location