CAL<n>:OUTP:FREQ:CURR7 <value-7>

26. Perform the voltage calibration:

CAL<n>:OUTP:FREQ:CALC

27. Send the system error query command to make sure calibration was successful:

SYST:ERR?

28. If there is no error returned at the system error query command then save the

calibration data

CAL<n>:UNLOCK “6867”

CAL<n>:STORE

CAL<n>:LOCK

29. Reset the unit

*RST<n>