5 environmental characteristics, Operating environmental conditions – AMETEK ReFlex User Manual

Page 33

Advertising
background image

ReFlex Power™

System Overview

M380056-01 Rev J

1-11

Hold-Up Time

10ms, with dropout of AC input at full output power except

RFP-D2050-025-xxxx: 8

ms, with dropout of AC input at full output power

Aggregate Output Power

Depends on module complement and input voltage: With AC input
voltage

≥ 200VAC or DC input, 6kW maximum; with AC input voltage

< 200VAC, 3.6kW maximum

1.3.5

E

NVIRONMENTAL

C

HARACTERISTICS

The ReFlex Power™ system has been ruggedized to MIL-PRF 28800F
requirements for Class 3. It is capable of operating in military
environments, with enhanced capabilities to withstand harsh
environmental conditions of temperature, altitude, shock/vibration, and
input power.

O

PERATING

E

NVIRONMENTAL

C

ONDITIONS

Temperature:

Standard: 0 to 50

°C

Extended Range Option: -10 to 55

°C

Altitude:

Standard: 0 to 6,500 feet

Extended Range Option:

Low-Power DC, High-Power DC, Fixed-Power DC, AC Power, and
Low-Power Load assets: 0 to 15,000 feet

High-Power Load asset: 0 to 15,000 feet, with linear temperature
derating from 55

°C at 6,500 feet to 40°C at 15,000 feet, or with linear

power derating from 750W at 6,500 feet to 600W at 15,000 feet

Humidity:

95% non-condensing

Shock:

Class 3 MIL-PRF-28800F

Vibration:

Class 3 MIL-PRF-28800F

Operation Without Fully Populated Mainframe:

If Mainframe is not fully populated with modules, filler panels must be
installed in empty slots to maintain proper airflow and structural
integrity.